12/24/40.5kV Fonotaga Tapuni ma Fesootaiga
Fa'apipi'i Fono 5GP.320.010 Fa'apipi'i Ata
(800mm le lautele o lo'o tu'u i le vaeluagalemu)
Shutter Assembly 5GP.320.010 Lisi Fa'atonu
Leai. | Igoa | Tusitala Nu. | Qty.(pc/set) |
1 | Fa'amau sa'o lagolago | 8GP.123.011 | 1 |
2 | Sa'o so'otaga ipu | 5GP.235.011 | 1 |
3 | Fa'ailoga pine | 8GP.866.014 | 1 |
4 | So'oga agavale | 5GP.235.010 | 1 |
5 | Fa'amau lagolago agavale | 8GP.123.010 | 1 |
6 | So'oga uelo | 5GP.174.016.1(Mo VD4) | 2 |
5GP.174.016.2(Mo GPVN) | |||
5GP.174.016.3(Mo VB2) | |||
7 | I lalo faitotoa tapuni | 8GP.320.010 | 1 |
8 | poloka poloka 8 | DK-8 | 8 |
9 | Papa puipui | 8GP.123.013 | 3 |
Leai. | Igoa | Tusitala Nu. | Qty.(pc/set) |
10 | So'oga uelo | 5GP.174.017.1(Mo VD4, 40kA) | 2 |
5GP.174.017.2(Mo VD4, 31.5kA) | |||
5GP.174.017.3(Mo GPVN) | |||
5GP.174.017.4(Mo VB2) | |||
11 | Fa'ailoga pine | 8GP.866.012 | 1 |
12 | Fa'ailoga pine | 8GP.866.013 | 2 |
13 | Papa puipui | 8GP.123.012 | 3 |
14 | Tapuni pito i luga | 8GP.320.011 | 1 |
15 | Tootoo taiala | 8GP.234.011(Mo VD4, GPVN) | 2 |
8GP.234.011.1(Mo VB2) | |||
16 | lima taofi | 8GP.210.011 | 2 |
Isi fa'amatalaga tapuni fa'atulagaina lisi
Code | 5GP.320.010.1 | 5GP.320.010.2 | 5GP.320.010.3 | 5GP.320.010.4 | 5GP.320.010.5 |
Lautele o le Kapeneta | 650mm | 700mm | 840mm | 900mm | 1000mm |
faitotoa pito i luga | 8GP.320.011.1 | 8GP.320.011.2 | 8GP.320.011.3 | 8GP.320.011.4 | 8GP.320.011.5 |
I lalo faitotoa | 8GP.320.010.1 | 8GP.320.010.2 | 8GP.320.010.3 | 8GP.320.010.4 | 8GP.320.010.5 |
Fonotaga tapuni 5GP.320.011
(1000mm le lautele o lo'o tu'u i le mea e sui ai)
Masini Mechanism Shutter 5GP.320.011 Lisi Fa'atonu
(1000mm le lautele o lo'o tu'u i le mea e sui ai)
Leai. | Igoa | Tusitala Nu. | Qty.(pc/set) |
1 | Fa'amau sa'o lagolago | 8GP.123.276 | 1 |
2 | Sa'o so'otaga ipu | 5GP.235.012 | 1 |
3 | Fa'ailoga pine | 8GP.866.014 | 1 |
4 | Pepa feso'ota'iga agavale | 5GP.235.013 | 1 |
5 | Fa'amau lagolago agavale | 8GP.123.275 | 1 |
6 | Feso'ota'iga fa'atasi fa'atasi | 5GP.174.281 | 2 |
7 | I lalo tapuni | 8GP.320.273 | 1 |
8 | poloka poloka 10 | DK-10 | 8 |
Leai. | Igoa | Tusitala Nu. | Qty.(pc/set) |
9 | Papa puipui | 8GP.123.278 | 3 |
10 | So'oga uelo so'oga | 5GP.174.282 | 2 |
11 | Fa'ailoga pine | 8GP.866.012 | 1 |
12 | Fa'ailoga pine | 8GP.866.013 | 2 |
13 | Papa puipui | 8GP.123.277 | 3 |
14 | Tapuni pito i luga | 8GP.320.274 | 1 |
15 | Tootoo taiala | 8GP.234.272 | 2 |
16 | lima taofi | 8GP.210.011 | 2 |
Isi fa'amatalaga tapuni fa'atulagaina lisi
Code | 5GP.320.011.1 | 5GP.320.011/JY | 5GP.320.011.2 | 5GP.320.011.3 |
Lautele o le Kapeneta | 800mm | 1000mm(Insulate) | 1100mm | 1200mm |
faitotoa pito i luga | 8GP.320.274.1 | 5GP.320.275 | 8GP.320.274.2 | 8GP.320.274.3 |
I lalo faitotoa | 8GP.320.273.1 | 5GP.320.275.1 | 8GP.320.273.2 | 8GP.320.273.3 |
Manatua: 5GP.320.275 mo insulating shutter e SMC ipu i le ogatotonu ma pito uma i le ipu uamea, isi faʻapotopotoga tapuni pe a manaʻomia insulating faitotoa faʻamolemole faʻamaonia.
Faiga fa'aogaina o le fa'aeleeleele masini feso'ota'i (Mo le fa'aogaina o le ta'avale lima) 5GP.363.010.1 ata fa'apotopotoga
Fa'atonuga o le Mea Fa'apipi'i
O lo'o fa'aopoopoina le masini fa'afeso'ota'i le feso'ota'iga i tua ma le faitoto'a pito i tua lea na fa'atūina i luga o le fa'avae o le 5GP.363.010 le fa'aogaina ole fa'aogaina ole lalolagi ole masini fa'aogaina.O lona uiga, ina ua tapunia le ki earthing ma tatala le faitotoa pito i tua (faamaufaailoga ipu), o le uluai interlock e mafai lava ona faagaoioia le ki earthing, ae le mafai e lenei interlock.E tatau ona e tapuni muamua le faitotoa pito i tua (mea fa'amaufa'ailoga) ina ia fa'agaoioia le ki fa'alelalo.
O taʻiala galue o le masini fesoʻotaʻi ua suia le lima loka Numera 24 i le mea na faʻaalia i le taumatau ma faʻaopoopo le tautotogo i luga o le faavae o le 5GP .363.010 muamua.A matala le faitotoa pito i tua (fa'amaufa'ailoga), o le lima loka e ulufale atu i totonu o le pu sikuea o le kapeneta (fautuaina lapo'a 35X35), e le mafai ona fa'agaoioia le ki.
Fa'agaoioi ole fa'aeleele ole fa'aogaina masini feso'ota'i (Mo feso'ota'iga ta'avale lima)
5GP.363.010.1 lisi fa'atulagaina.
Leai. | Igoa | Tusitala Nu. | Qty.(pc/set) |
1 | Tuuina atu | 8GP.263.011 | 1 |
2 | Vaega | 8GP.192.010 | 1 |
3 | Vaega | 8GP.192.011 | 1 |
4 | Lima tu'i | 8GP.210.014.1 | 2 |
5 | Vaega | 8GP.151.041 | 1 |
6 | Lima tu'i | 8GP.211.061 | 1 |
7 | Vaega | 8GP.151.039 | 1 |
8 | Lima tu'i | 8GP.211.062 | 1 |
9 | Fa'amau M5×12 | GB70-85 | 1 |
10 | Vaega | 8GP.151.042 | 1 |
11 | Vaega | 8GP.151.043 | 1 |
12 | Tootoo gaogao | 8GP.200.013.1 (Uumi 1432 mo le kapeneta loloto 1500 loloto) | 1 |
8GP.200.013.2 (Lumi 1590 mo le loloto o le kapeneta 1660) | 1 | ||
13 | Papa lagolago | 8GP.161.058 | 1 |
8GP.161.058.1(Mo le filifiliga) | 1 |
Leai. | Igoa | Tusitala Nu. | Qty.(pc/set) |
14 | Ufiufi | 8GP.017.011.1 | 1 |
15 | puipui | 5GP.043.022 | 1 |
16 | Papa lagolago | 8GP.161.059 | 1 |
17 | Fa'ase'e | 8GP.143.010 | 2 |
18 | Lima tu'i | 8GP.211.058 | 1 |
19 | lima taofi | 8GP.211.057 | 3 |
20 | Fa'avae lagolago | 8GP.043.019 | 1 |
21 | Tapuni faailoa | 8GP.866.010 | 1 |
22 | Fa'atasiga tootoo feso'ota'iga | 5GP.233.030.1 | 1 |
5GP.233.030.3(Mo le filifiliga) | 1 | ||
23 | Tatala fa'ailoga | 8GP.866.011 | 1 |
24 | Loka lima | 8GP.211.201 | 1 |
25 | Pepa fusi nifo | 8GP.151.044 | 1 |
26 | Lima tu'i | 8GP.211.060 | 2 |
27 | Tag | 8GP.860.010 | 1 |
28 | Omiga puna | 8GP.282.201 | 1 |
29 | Loka lima fa'apipi'i Bolt | 8GP.920.002 | 1 |
Fa'aaliga:
1. Numera 1~12 va'ai i le itulau muamua.
2. No. 22 Fa'apotopotoga tootoo feso'ota'iga, o le lima feso'ota'iga e lua lapo'a: O le mamao o le ogatotonu o le Kapeneta 60mm tutusa.Afai e mana'omia le mamao ole 80mm fa'amolemole siaki le itulau 17 le fa'atonuga o le fa'apotopotoga o lima, ma fa'ama'oti pe a oka.
Fa'agaoioi ole fa'aogaina ole fa'aeleele'ele masini feso'ota'i (Mo le fa'agaioia o mea fa'apipi'i) 5GP.577.1001
Faiga fa'aeleelea fa'aogaina masini feso'ota'i masini (Mo le fa'agaioia o mea fa'apipi'i ta'avale) 5GP.577.1001 lisi fa'atulagaina
Leai. | Igoa | Tusitala Nu. | Qty.(pc/set) |
1 | Tuuina atu | 8GP.263.011 | 1 |
2 | ipu taofi | 8GP.151.084 | 2 |
3 | Lima tu'i | 8GP.210.014.1 | 2 |
4 | Vaega | 8GP.151.041 | 1 |
5 | Lima tu'i | 8GP.210.014.2 | 1 |
6 | Fa'amau M 5X12 | GB70-85 | 1 |
7 | Vaega | 8GP.151.042 | 1 |
8 | Vaega | 8GP.151.043 | 1 |
9 | Lima tu'i | 8GP.210.014.3 | 1 |
Leai. | Igoa | Tusitala Nu. | Qty.(pc/set) |
10 | lima taofi | 8GP.210.322 | 1 |
11 | Tootoo gaogao | 8GP.174.214 | 1 |
12 | Ufiufi | 8GP.017.011.2 | 1 |
13 | Fa'avae lagolago | 5GP.043.022 | 1 |
14 | Fa'ase'e | 8GP.143.010 | 2 |
15 | Papa lagolago | 8GP.161.059 | 1 |
16 | Papa lagolago | 8GP.161.058 | 1 |
17 | Pepa fusi nifo | 8GP.151.044 | 1 |
18 | Tag | 8GP.860.010 | 1 |
Manatua: 1. O lenei masini e manaʻomia ona fesoʻotaʻi ma le faitotoa i lalo, faʻamolemole faʻamaonia pe a oka.