MNS Low Voltage Aveese MCC Switchgear
GPM1 Maualalo-Valuelue Aveese Suiga
GPM1 la'ititi la'ititi la'ititi e mafai ona fa'amulimuli o le fa'atekonolosi fa'afeso'ota'i maualalo a le ABB.
GPM1 o se faʻapipiʻi faʻapitoa, tele-functional low voltage distribution cabinet i le lalolagi e sili atu nai lo le 40 tausaga o faʻagaioiga talafaasolopito, faʻaaogaina lautele i metallurgy, suauʻu, vailaʻau, fale gaosi oloa ma mining pisinisi, ma atinaʻe mo taimi uma e manaʻomia ai le maualuga o le faʻatuatuaina o faiga maualalo-voltage. , tufatufaina atu o le eletise ma faiga fa'atonutonu afi.
O lenei masini o se falegaosimea faʻapipiʻi faʻapipiʻiina modular low-voltage switchgear mo AC 50-60Hz, faʻamauina le voltage galue 600V ma lalo ifo o le eletise mo le gaosiga o le eletise, faʻasalalau, tufatufa, suiga o le eletise ma le faʻaogaina o le eletise o meafaigaluega faʻaaogaina.
GPM1 cabinet e sili ona fetuutuunai, e mafai ona faʻapipiʻiina i le tele o faʻataʻitaʻiga ma faʻamatalaga o vaega e tusa ai ma manaoga faʻapitoa ma taimi eseese.I le isi itu, e mafai ona e faʻalagolago i ituaiga eseese o mea eletise eletise faʻapipiʻi i totonu o le koluma lava e tasi poʻo le kapeneta tutusa e pei ona faʻafefiloi faʻatasi ai le fafaga fafaga ma le taʻavale afi.
GPM1 low-voltage withdrawable switchgear o se vaega atoa o lalaga eletise maualalo, faiga maualalo-voltage e talafeagai mo 5000A uma o loʻo iai nei pe itiiti.
Drawers: 8E/4, 8E/2, 8E, 12E, 16E, 20E, 24E mo fuafuaga a le kapeneta ma filifiliga eseese.
Fonotaga Fa'atino Vaega
Fa'asologa o le tele o galuega fa'alava palasitika o lo'o fa'aputuina i le va o le potu fa'atūtū autu ma le potu eletise.
Faia i mea fa'ainisinia vevela ma foliga.O loʻo i ai foliga o le anti-afi, malosi, maualuga malosi ma le maualuga o le anti-impulse ma galuega o le aloese mai le faʻaogaina o faʻalavelave faʻafuaseʻi e mafua mai i le va o le arc ma le taʻavale autu na tulaʻi mai i le faaletonu.
O lona fua faatatau voltage o le 380V (660V), ma le maualuga o le eletise o loʻo i ai nei o le 176KA, ma le taimi puupuu o le eletise o loʻo i ai nei o le 50kA ~ 80kA (1s).O vaega e tele galuega tauave a pasi auala ipu (5GP 742 001) ua tuufaatasia i le 9 pito ogatotonu, 2 alalaupapa pito, pa'u ka'u fasi pepa ma papa.E mafai foi ona iloa le faʻafefiloi faʻapipiʻiina o le kapeneta PC ma le kapeneta MCC.Afai e sui le pito i luga o le alalaupapa i se ipu vavae, o le a faʻaaogaina i le 600 lautele MCC pito i tua o fafo e mafai ona aveese.
O nei oloa e faia i mea sili ona malosi ma fa'aaoga masani i le fa'apipi'iina o le 50mm × 30mm × 5mm L ituaiga fa'atūtū autu autu.