12/24/40.5kV Fa'aeleele Suiga
Tulaga Galuega Fa'ata'atia
1. Ole maualuga ole sami ole maualuga ole 1000m;
2. Ea ambient vevela: + 45 ℃,-25 ℃;
3. Malosi o seismic e le sili atu i le 8 tikeri;
4. Susū fa'atatau i aso ta'itasi tau averesi e le sili atu i le 95%, averesi masina e le sili atu i le 90%;
5. Vasega filogia: II
Tulaga faʻapitoa: Faʻamolemole faʻamaonia pe a oka.
12kv Loto Malo maualuga Voltage Ac Earthing Suiga
Fa'amatalaga Fa'ainisinia Autu
Aitema | Vaega | Fa'amaumauga | ||
Fuafuaina voltage | kV | 12 | ||
Fa'atatauina mo se taimi pupuu e tetee atu i le taimi nei | kA | 31.5 | ||
Fuafuaina le umi o le li'o pu'upu'u | s | 4 | ||
Fa'atatauga fa'aa'au tapuni tapuni | kA | 80 | ||
Fa'atatau pito maualuga e tetee atu i le taimi nei | kA | 80 | ||
Fuafuaina tulaga insulation | Fa'atauaina le mana puupuu | kV | Vaega i le eleele/va o vaega | 42 |
Fa'atatauina fa'aoso moli e fa'afitia le voltage | 75 | |||
Onosa'i fa'ainisinia | Taimi | 2000 |
Fa'amatalaga Fa'apitoa
GPJN15-12/31.5 Fa'asinomaga suiga ole eleele ma le fa'apipi'iina
GPJN15A-12/31.5 Fa'asologa o suiga ole eleele ma le tele fa'apipi'i
24kv Loto Maualuga Voltage AC Eleele Suli
Fa'amatalaga fa'atekinisi autu
Aitema | Vaega | Fa'amaumauga | ||
Fuafuaina voltage | kV | 24 | ||
Fa'atatauina mo se taimi pupuu e tetee atu i le taimi nei | kA | 31.5 | ||
Fa'atatauga fa'aa'au tapuni tapuni | kA | 80 | ||
Fa'atatau pito maualuga e tetee atu i le taimi nei | kA | 80 | ||
Fuafuaina le umi o le li'o pu'upu'u | s | 4 | ||
Fuafuaina tulaga insulation | 1min Malosiaga fa'afefete fa'afefe voltage | kV | Vaega i le eleele/va o vaega | 65 |
O le fa'aoso o moli e tetee atu i le voltage | 125 | |||
Onosa'i fa'ainisinia | taimi | 2000 |
GPJN15-24/31.5 Fa'asinomaga suiga ole eleele ma le fua fa'apipi'i
40.5kv Loto Maualuluga Voltage AC Earthing Suiga
Fa'amatalaga fa'atekinisi autu
Aitema | Vaega | Fa'amaumauga | ||
Fuafuaina voltage | kV | 36/ 38/40.5 | ||
Fa'atatauina mo se taimi pupuu e tetee atu i le taimi nei(4s) | kA | 31.5 | ||
Fa'atatauga fa'aa'au tapuni tapuni | kA | 80 | ||
Fa'atatau pito maualuga e tetee atu i le taimi nei | kA | 80 | ||
Vaega mamao | mm | 300, 350, 400 | ||
Fuafuaina tulaga insulation | (1min) Malosi'i fa'afefete fa'afefete | kV | Vaega i le eleele/va o vaega | 95 |
O le fa'aoso o moli e tetee atu i le voltage | 185 |
Otootoga ma le fua fa'apipi'i
GPJN15-12(24)(40.5)kV Su'i Fa'aleeleele
GPJN15-12(24)/D31.5, GPJN15-12/D40, 50, GPJN15-40.5/D31.5 fa'asologa i totonu o le fale eletise maualuga eletise eletise (pu'upu'u e pei o: afi afi afi) ua mamanuina mo le manaoga switchgear atamai o le faiga eletise.E fetaui mo le 3 ~ 40.5KV, 3 vaega, AC 50 (60) Hz faiga eletise ma ituaiga o eletise eletise maualuga.E talafeagai mo le maualuga voltage switchgear faatulagaga e pei o le puipuiga o le eleele pe a tausia.
O le faatinoga o oloa e fetaui ma GB1985-2004 High Voltage AC Disconnector ma Earthing Switch ma manaoga o tulaga masani faapea foi IEC62271-102:2002.
Earthing fausaga suiga e faigofie ma fa'atusatusa, mama mama, fa'agaioiga fetuutuunai, fa'apipi'i faigofie, mautu fa'avevela malosi, ma se fa'agaioiga eletise fa'atuatuaina, tausia le ulua'i feso'ota'iga i le pu'eina o lapiti switchgear filifili tumau, ua avea ma pateni a le atunu'u.
Oloa Fa'ata'ita'iga ma Lona Uiga
Parameter Autu
Fa'ata'ita'iga o oloa | GPJN15 | ||||
Fuafuaina galuega voltage | 12kV | 24kV | 40.5kV | ||
Fuafuaina puupuu-taimi tetee i le taimi nei (4S) | 31.5kA | 40kA | 50kA | 31.5kA | |
Fa'atatau pito maualuga e tetee atu i le taimi nei | 80kA | 100kA | 125kA | 80kA | |
Fa'atatauga fa'aa'au tapuni tapuni | 80kA | 100kA | 125kA | 80kA | |
Tulaga insulating: | Lisi autu e taofiofia le voltage(1min) | 42kV | 65 kV | 95kV | |
Fa'atatauina fa'aoso moli e fa'afitia le voltage | 75kV | 125 kV | 185kV | ||
I le isi itu mamao pe a uma ona tatala ia le itiiti ifo | 125mm | 200 mm | 300mm | ||
Pulea voltage | AC220V | DC220V | DC110V |