GPN1-12kV Ave'esea AC uamea fa'aofuina Switchgear
Tulaga si'osi'omaga
Ambient vevela: -25 ℃ ~ + 45 ℃, averesi i aso uma: ≤35 ℃
Maualuluga: 1000m(Tulaga masani);e mafai ona oʻo atu i le 4500m mo faʻatonuga faʻapitoa;
Susū fa'atatau: averesi aso uma ≤95%, averesi masina ≤90%;
Malosi o le mafuie ≤8 tikeri;
O taimi fa'atatau e tatau ona sa'oloto mai mea e mu, mea pāpā, fa'a'ele'ele ma tete'e tele.
Fa'ata'ita'iga
Fa'ailoga oloa
1) O lenei oloa e talafeagai mo a tatou lava GPVN-12kV/17Kv/24kV fa'apipi'i po'o le fa'amama lima vacuum circuit breaker po'o le VD4 vacuum circuit breaker a le ABB.
2) O la matou gaosiga faʻapipiʻi GPVC masini faʻafesoʻotaʻi - fuse faʻatasi poʻo le kamupani ABB VC vacuum contactors, lea e mafai ona aofia ai FC matasele pupuni, e faʻafeiloaʻi ai le eletise o le eletise ma manaʻoga o isi pisinisi faʻapisinisi ma mining.
3) Faʻaaogaina le sili atu le alumini-zinc faʻapipiʻiina ipu uʻamea e saʻo CNC masini masini faʻapipiʻi i totonu o le kapeneta, ma le faʻaogaina o le faʻaluaina o le faʻagasologa o le punou, faʻaleleia atili le malosi o le kapeneta.
4) Faʻasagaga o le faitotoʻa e ala i le epoxy resin electrostatic powder spray process, teteʻe o le pala, faʻamaʻi, aʻafiaga ma le pipii malosi.
5) O lo'o fa'apipi'iina atoatoa le fausaga o le kapeneta ua fa'aaofuina atoatoa, o vaega fa'atino ua vavae'ese atoa.Pe a tapunia le faitotoa, e mafai ona ausia le faagaoioiga o le breaker ma le earthing ki.
6) Sa'o le masini sikulima, fa'amautinoa le ta'avale fa'atasi ma le fa'afeso'ota'i lelei.
7) Fuafuaga muamua atoatoa e faʻafetaui ai manaʻoga eseese o tagata faʻaoga, ma mafai ai ona faʻaluaina fuafuaga taʻavale.
8) Kilia vave fa'avae mo le fa'aogaina o le eleele ma le pupuu, ma ia ausia le eletise (Motorized).
9) Faigofie ma aoga "Lima Saogalemu" masini fesoʻotaʻi e mafai ona faʻatuatuaina puipuia le faʻaoga sese ma faʻamautinoa le saogalemu o le tagata faʻafoe.
10) Switchgear e patino i le Arc-fa'amaonia ituaiga, i luga o le pito i luga o le vaega pasi, vacuum vacuum va'a vaega, ma uaea vaega fa'apipi'iina ma masini fesoasoani mamafa.
11) Vaega uaea e tele avanoa, e mafai ona faigofie ona fesootai i se plurality o uaea, ma ia mautinoa le maualuga faapipiiina o le polo uaea.
12) Fa'atonu le puipuiga (IP4X), e puipuia lelei ai mea mai fafo po'o osofa'iga fa'ama'i.
13) Faiga lua filifiliga mulimuli i le masini mataʻituina le saogalemu o loʻo i ai se galuega faʻapitoa-diagnostic ma fesoʻotaʻiga faʻamatalaga, komepiuta faʻapipiʻi atamai, e ausia ai le mamao mamao, telemetry mamao, vaʻavaʻai mamao, fetuutuunaiga mamao.
14) Faʻafeiloaʻi GB3906, GB / T11022, DL404 ma IEC60298, IEC62271-1 tulaga faʻataʻitaʻiga, ma e ala i se faʻataʻitaʻiga suʻega suʻega ma suʻega faʻafanua (3000 m).
15) Na pasi su'esu'ega feso'ota'iga electromagnetic i le falesu'esu'e su'esu'ega masini eletise.
A.Fa'amatalaga fa'apitoa Mo 12Kv switchgear
Aitema | Vaega | Fa'amaumauga | |
Fuafuaina voltage | kV | 6~12 | |
Fa'atatau taimi | Hz | 50/60 | |
Fa'atatau i le taimi nei | A | 630~4000 | |
Fuafuaina tulaga insulation | 1min le tele o le malosi (Vaega i le lalolagi / i luga o fesoʻotaʻiga tatala) | kV | 42/48 |
O le uila e tetee atu i le voltage (Vaega i le lalolagi/i luga o feso'ota'iga tatala) | kV | 75/85 | |
O le pasi autu ua fa'atatau i le taimi nei | A | 1250,1600,2000,2500,4000 | |
Sub-busbar fa'atatau i le taimi nei | A | 630,1250,1600,2000,2500,3150 | |
Fa'atatauina le taimi pu'upu'u e fa'afeagai ai le taimi nei(4s) | kA | 16,20,25,31.5,40,50 | |
Fa'atatau pito maualuga e tetee atu i le taimi nei | kA | 40,50,63,80,100,125 | |
Faailoga puipuiga | Puipuia IP4X, IP2X(VCB tatala faitotoa) | ||
Fuafuaga (lautele/loloto/maualuga) | mm | 650(800,1000) /1500(1300,1670,2000) /2300 | |
mamafa | kg | 500~1200 |
Fa'atulagaina ata o le cubicle 630A~1250A
Fa'atulagaina ata o cubicle 1600A~4000A
B.Main laulau fa'atekinisi mo 17.5kV switchgear
Leai. | Igoa | Vaega | Fa'amaumauga | |
1 | Fuafuaina voltage | kV | 15/17.5 | |
2 | Fuafuaina tulaga insulation | 1 min le malosi fa'avevesi fa'afitia voltage (RMS) | kV | 50 |
O le malosi o moli e tetee atu i le voltage (tulaga maualuga) | 95 | |||
3 | Fa'atatau i le taimi nei | A | 630~4000 | |
4 | Fa'atatauina le la'au fa'alatalata pupuu | kA | 50 | |
5 | Fa'atatau ole malosi ole taimi | Hz | 50/60 | |
6 | Fa'atatauina le la'au fa'aa'ai pupuu (peak) | kA | 130 | |
7 | Fa'atatau pito maualuga e tetee atu i le taimi nei | kA | 130 | |
8 | Fa'atatauina mo se taimi pupuu e tetee atu i le taimi nei | kA | 50 | |
9 | Ola eletise | taimi | 20 | |
10 | Fa'avasegaina le umi ole taimi nei | s | 4 | |
11 | Ole ola ole VCB | taimi | 10000 | |
12 | Puipuiga tikeri o le potu | Puipuia IP4X, IP2X(VCB tatala faitotoa) | ||
13 | Fua fa'atatau (W*D*H) | mm | 800/1000*1500/1670*2300 | |
14 | mamafa | kg | 500~1200 |
C.Fa'amatalaga fa'apitoa mo le 24kV switchgear
Aitema | Vaega | Fa'amaumauga | |
Fuafuaina voltage | kV | 24 | |
Fa'atatau taimi | Hz | 50/ 60 | |
Fa'atatau i le taimi nei | A | 630,1250, 1600, 2500, 3150, 4000 | |
Fuafuaina tulaga insulation | 1min le tele o le malosi (vaega i le lalolagi / i luga o fesoʻotaʻiga tatala) | kV |
65 |
O le uila e tetee atu i le voltage (vaega i le lalolagi / i luga o fesoʻotaʻiga tatala) | kV |
125 | |
Fa'atatauina le taimi pu'upu'u e fa'afeagai ai le taimi nei(4s) | kA | 20, 25, 31.5 | |
Fa'atatau pito maualuga e tetee atu i le taimi nei | kA | 50, 63, 80 | |
Faailoga puipuiga | Fa'amau: IP4X, tatala faitotoa: IP2X | ||
Fuafuaga (lautele x loloto x maualuga) | mm | 1000(800)x1820(1500)x2430(2300) | |
mamafa | kg | 1200-1500 |
1. E tatau ona va'ava'ai ese'ese le malosi o le ta'amilosaga pupuu o le CT;
2. O le ata o le laina pito i tua i luga o le ulu e tatau ona i ai se potu faaopoopo.