GPN2S/GPN2E-40.5kV ituaiga Kesi Kesi Insulated Switchgear
Aotelega
O le Kesi Insulated Switchgear (CGIS) i totonu, falegaosimea, fa'apipi'i u'amea, fa'apipi'i kesi fa'apipi'i mo fa'aoga ta'avale tasi, e aofia ai le "Green Type" GPN2E-40.5, GPN2N-40.5 ma le "Standard Type" GPN2S- 40.5.
O le "Green type" GPN2N-40.5 ua faʻafouina e faʻaaoga ai le nitrogen mama e pei o le kasa faʻapipiʻi mo le oloa faʻasologa ma le Non-SF6 kasa faʻatekonolosi, lea na aumaia ai le puipuiga moni o le siosiomaga o le kesi insulated switchgear.
O le "Green type" GPN2E-40.5 o loʻo tuʻufaʻatasia ai tekonolosi faʻafefiloi faʻafefiloi gas-insulated (SF6 + N2) ma vacuum breakers, faʻatagaina meafaigaluega e faʻaogaina i se tulaga sili atu ona faʻatuatuaina ma faʻalelei.
O le "Standard type" GPN2S-40.5 o le 100% SF6 insulated, maualuga le faʻatinoga ma faigofie faʻaoga.
Fa'atasi ai ma le gaosiga fa'aonaponei fa'aonaponei ma fa'ata'ita'iga otometi fa'atasi ma le masini, mata'itu ma puipuiga tekonolosi, CGIS e fetaui lelei mo mana'oga fa'asoa eletise.O le CGIS e fetaui lelei i alamanuia e maualuga le fa'atuatuaina mana'omia e pei ole Power Networks, Mining, Rail Transportation, Petrochemical Plants, Wind Farms ma Metropolitan Rail Systems.
Tulaga masani o galuega
O le switchgear e faʻavaeina mo tulaga masani o auaunaga mo totonu ole switchgear ile GB 3906, DL/T404 ma le IEC 62271-200.O tau fa'atapula'a nei, fa'atasi ai ma isi, fa'aaoga:
Ea malulu
Maualuluga ole vevela ole ea: +45℃
Laiti ole vevela ole ea: -25℃
Ole maualuga ole vevela ole aso: +35℃
Susū:
Tau fa'aaso uma ole susū fa'atatau: ≤ 95%
Fa'alemasina averesi tau ole susū fa'atatau: ≤ 90%
O aso ta'itasi tau o le ausa vai: ≤ 2.2×10-3MPa
Tau fa'alemasina ta'i masina o ausa vai: ≤ 1.8×10-3MPa
Maualuluga: ≤ 1000m
O le ea o loʻo i totonu e leʻo faʻaleagaina tele i le pefu, asu,
kasa pala ma/po'o le mu, ausa po'o le masima.
Tulaga auaunaga faapitoa
E mafai foi ona faʻaaogaina le oloa mo le tele o tulaga faʻapitoa auaunaga.
Afai o tulaga o auaunaga e sili atu i tulaga masani o auaunaga, e le o iai i le GB 11022 ma le IEC 62271-1, faʻamolemole faʻafesoʻotaʻi muamua le GP mo le faʻamaoniga:
Maualuluga maualuga atu i le 1000m.
maualuga le vevela o le siosiomaga.
Maulalo le vevela o le siosiomaga.
O isi tulaga fa'apitoa tau si'osi'omaga.
Fa'aitiitia le kasa oona
O le CGIS o lo'o tu'ufa'atasia ai tekonolosi fa'aonaponei o le Nitrogen mama po'o le kesi fefiloi fa'afefiloi (SF6 + N2) ma vacuum breakers, o se filifiliga taua na faia e le GP e fesoasoani i le fa'aitiitia o le a'afiaga o le greenhouse.O le SF6 (sulphur-hexafluoride) o lo'o i le lisi o kasa kasa i le Kyoto Protocol, ma le Global Warming Potential (GWP) e 23,000.O le tele o isi mea fa'aoga eletise eletise e fa'aaogaina le kesi SF6 e na'o le pau lea o le mea e fa'amama ai.O le tafe mai o le kasa SF6 mai le mea e sui ai mea e saofagā ai i le fa'amata'u o a'afiaga o le greenhouse ma suiga o le tau.
Faatasi ai ma la matou tautinoga i le puipuiga o le siosiomaga, e fesoasoani le CGIS i le faʻaitiitia o kasa kesi e ala i le faʻaogaina o tekonolosi faʻafefiloi faʻatasi ma tekinolosi faʻafefe.
O le 100% poʻo le 50% faʻaitiitiga i le SF6 e maua e ala i le faʻaaogaina o le Nitrogen (N2) faʻafefiloi kesi-insulated breakers.O le Nitrogen o le vaega pito sili lea ona tele o le ea ma o lona fa'apalapala arc e le o'ona.Fa'atasi fa'atasi e so'otaga fa'apipi'i ma le natura fa'apitoa o paneli e fa'amautinoa ai le faigofie o le fa'apipi'iina ma le fa'aopoopoina e aunoa ma le mana'omia o ni gaioiga fa'aopoopo e fa'afoeina le kesi i luga o le saite.
Fa'amanuiaga
●70% Fa'aitiitiga i le Tele o Suiga
O se fa'ata'ita'iga fa'aeletise fa'alelei fa'atasi ma le fa'aogaina lelei o le fa'aogaina, e maua ai se mea fa'apipi'i komipiuta e fa'agaoioia saogalemu ma fa'alagolago.
Fa'asao le 70% avanoa pe a fa'atusatusa i le ea-insulated switchgear.
E faigofie le toe fa'aleleia i le potu sui o iai.
Fa'aitiitia le tau o fanua fa'asao.
●Maxile Saogalemu mo le fa'afoe ma Meafaigaluega
Ole mamafa ole galuega ole potu ole 0.00MPa(20℃).O lona uiga, e tusa lava pe i lalo o ia tulaga ogaoga, o loʻo tumau pea le maualuga o le insulation faʻamauina ma faʻatumauina uma ana galuega faʻatatau.Fa'afetai i le maualalo o le mamafa o le kesi, e tusa lava pe sola ese le kesi mai le kiliva, e mafai lava ona faʻaauau pea le faʻamalosi o le pusa.O fesoʻotaʻiga eletise ma masini faʻalagolago ua mamanuina i le va o le vaeluaga ma le tolu-tulaga ki e puipuia ai le faʻaogaina.
●Fa'agofie Fa'apipi'i/Taulalo Fa'agaioiga Ma Tausia Tau
Panels i le ogatotonu e mafai ona faigofie ona aveese mo le tausiga e aunoa ma le feaveaia panels tuaoi, faateleina avanoa.
Vaega Fa'atekinisi
lautele | Vaega | Tulaga masani GPN2S-40.5 | Ituaiga lanu meamata GPN2E-40.5 | Ituaiga lanu meamata GPN2N-40.5 | |
Fuafuaina voltage | kV | 36/38/40.5 | 36/38/40.5 | 36/38/40.5 | |
Fa'atatau ole malosi ole tele ole malosi ole eletise (1min) | I le eleele/vaega i lea vaega | kV | 95 | 95 | 95 |
I luga o le mamao tu'ufua | kV | 118 | 118 | 118 | |
I le eleele/vaega i lea vaega | kV | 185 | 185 | 185 | |
I luga o le mamao tu'ufua | kV | 215 | 215 | 215 | |
Fa'atatau taimi | Hz | 50/60 | 50/60 | 50/60 | |
Fa'atatau i le taimi nei | A | 1250, 2500, 3150 | 1250, 2500 | 1250, 2500 | |
Ta'atiaga ta'e faletupe capacitor tasi | A | 400/400 | 400/400 | 400/400 | |
Fa'ailoga uaea fa'atauina e malepe le taimi nei | A | 50 | 50 | 50 | |
Fa'avasegaina le la'au fa'ato'a fa'aletonu | kA | 20/25/31.5 | 20/25/31.5 | 31.5 | |
Fa'atatauina le ta'amilosaga pupuu o lo'o fa'atupuina le taimi nei (pu'upu'u) | kA | 50/63/80 | 50/63/80 | 80 | |
Fa'atatauina le taimi pu'upu'u e tetee atu i le taimi nei ma le tumau | kA/s | 20/3, 25/3, 31.5/3s | 20/3, 25/3, 31.5/3s | 31.5/3s | |
Fa'atatau pito maualuga e tetee atu i le taimi nei | kA | 50/63/ 80 | 50/63/ 80 | 80 | |
Fa'asologa o galuega | O-0.3s-CO-180s-CO | O-0.3s-CO-180s-CO | O-0.3s-CO-180s-CO | ||
Faiga kesi fa'a'ese'ese kesi | 100%SF6 | 50%SF6+50%N2 | 100%N2 | ||
Fa'aletausaga le leakage | %/Y | ≤ 0.1 | ≤ 0.1 | ≤ 0.1 | |
Fua fuaisa kasa (abs, 20˚C) | MPa | 0.12 | 0.12 | 0.12 | |
O'omi fa'alatalata (abs, 20˚C) | MPa | 0.11 | 0.11 | 0.11 | |
La'ititi o le mamafa o galuega (abs, 20˚C) | MPa | 0.10 | 0.10 | 0.10 | |
Tulaga o Puipuiga tane kesi | IP65 | IP65 | IP65 | ||
Puipuiga | IP4X | IP4X | IP4X | ||
O le afi ma le vili malaga Ose afi e fa'aola le afi | W | 90 | 90 | 90 | |
Fa'atatau le malosi o le vili tapuni | W | 220 | 220 | 220 | |
Fa'atatau le malosi o le coil tatala | W | 220 | 220 | 220 | |
Fuafuaina voltage o feso'ota'iga fesoasoani | V | DC 24, 48, 110, 220;AC220 | DC 24, 48, 110, 220;AC220 | DC 24, 48, 110, 220;AC220 | |
1 min ole malosi ole taimi e tetee atu ai i le voltage o fesoʻotaʻiga fesoasoani | kV | 2 | 2 | 2 | |
Fua ma le mamafa Fua (W×D×H)1250A | mm | 600×1600×2400 | 600×1500×2400 | 800×1700×2300 | |
Fua (W×D×H)2500A | mm | 800×1600×2400 | 800×1500×2400 | 900×1700×2300 | |
Mamafa 1250A | kg | 800 ~ 1000 | 800 ~ 1000 | 800 ~ 1000 | |
Mamafa 2500A | kg | 1100 ~ 1400 | 1100 ~ 1400 | 1100 ~ 1400 |
Fa'atulagaina o le tulaga masani GPN2S-40.5 ma lanu meamata ituaiga GPN2E-40.5
Tulaga masani GPN2S-40.5kV
Ituaiga lanu meamata GPN2E-40.5kV
1. Puipuiga ma le Pulea Vaega
2. Vaega eletise maualalo
3. VCB masini
4. Vacuum vacuum fa'apipi'i fa'apipi'i
5. Faitotoa vaega eletise maualalo
6. Fa'ailoga le mamafa o kasa
7. VCB tane kesi
8. 3-tulaga sui masini
9. 3-tulaga ki
10. Autu pasi
11. tane kesi autu o le busbar
12. Faavaa i luma
13. Si'i pu'e pu'e
14. Mea e fa'amama le mamafa o tane kesi autu
15. Toto-cone uaea pupuni
16. Uaea laina
17. Uaea
18. Ufi tua
19. Omiga fa'avevela masini o VCB tane kesi
20. CT
IST 3-tulaga masini
IST 3-tulaga ki
tane kesi GPN2S VCB
GPN2S-40.5 VCB
Fa'atulagaina o le tulaga masani GPN2S-40.5 ma lanu meamata ituaiga GPN2E-40.5Fa'asologa o le GPN2N lanu meamata (No-SF6)
Ituaiga lanu meamata GPN2N-40.5kV
1. Puipuiga ma pulea iunite
2. Vaega eletise maualalo
3. VCB masini
4. Vacuum vacuum fa'apipi'i fa'apipi'i
5. Faitotoa vaega eletise maualalo
6. Fa'ailoga le mamafa o kasa
7. VCB tane kesi
8. 3-tulaga sui masini
9. 3-tulaga ki
10. Autu pasi
11. tane kesi autu o le busbar
12. Faavaa i luma
13. Si'i pu'e pu'e
14. Mea e fa'amama le mamafa o tane kesi autu
15. Toto-cone uaea pupuni
16. Uaea laina
17. Uaea
18. Ufi tua
19. Omiga fa'avevela masini o VCB tane kesi
20. CT
21. Pa eleele
22. Voltage transformer (filifiliga)
Vacuum circuit breaker o lo'o fa'apipi'i fa'amau, a'o ona fa'atū-tolu-vaega fa'apipi'i pou o lo'o fa'apipi'i sa'o i totonu o le tane kesi motumotu.
Ona o le fa'aogaina o tekonolosi, o le arc e fa'atapula'aina i totonu o le vacuum interrupter, fa'aitiitia ai le tele o le gaogao o le kesi fa'amama.Ole suiga ole masini e maualuga le fa'atinoga i feso'ota'iga pu'upu'u masani ma le tele o fa'aoga e fesuia'i ai uta.